MyAdvantech Registration

MyAdvantech is a personalized portal for Advantech customers. By becoming an Advantech member, you can receive latest product news, webinar invitations and special eStore offers.

Sign up today to get 24/7 quick access to your account information.

Advantech WebAccess

Browser-based HMI/SCADA Software
  • Remote engineering and support with WebAccess Cloud Architecture
  • Business Intelligence Dashboard - cross-browser, cross-platform WebAccess HMI based on HTML5
  • Open Interfaces - Web Services, Widget Interfaces and WebAccess APIs
  • Excel Report integration for report format customization
  • Multi-touch gesture support
  • Google Maps and GPS location tracking integration
  • WebAccess Express- The auto-configuration tool for various devices
  • Distributed SCADA architecture with central database server and Multi-layer inter-operable SCADA nodes
  • Support ample drivers, including Advantech I/O, controllers and major PLCs
  • Redundant SCADA, ports and devices - High availability
  • Web-enabled video, audio and animation in WebAccess View
  • Open data connectivity by providing industrial protocol and ODBC integration
  • Advanced SCADA Function: Alarm, Schedule and Real-time database
Advantech WebAccess is a web browser-based software package for human-machine interfaces (HMI) and supervisory control and data acquisition (SCADA). All the features found in conventional HMI and SCADA software including Animated Graphics Displays, Real-time Data, Control, Trends, Alarms and Logs, are available in an standard web browser. WebAccess is built around the latest internet technologies.

The basic components are:
1. SCADA Node: it communicates in real-time with automation equipment and controls the equipment via serial, Ethernet or proprietary communication via multiple built-in device drivers. Not only does it run local controls and monitoring, but also provides real-time data to all remote clients.
2. Project Node: it is the development platform for WebAccess and is a web server for all clients to connect to the development project or remotely monitor and control the system. All system configuration, project database files and graphics are stored here.
3. Client node: through the ActiveX control inside Microsoft Internet Explorer, it monitors and controls the SCADA Node. The client connects to the Project Node and get the address of the SCADA Node, then communicates directly with the SCADA Node using proprietary communications over a TCP/IP connection. Data is displayed in real-time with dynamically animated graphics along with real-time, historical trending and alarm information. Users can acknowledge alarms and change set-points, status and other data.
4. Mobile Client: the Mobile Client interface is intended for use with smart mobile devices, such as iOS, Android; and Windows mobile devices. In the mobile client users can browse graphics, data-log trends, and tag information in real-time. Set value to tag or acknowledge alarms can also be supported via an intuitive interface.
WebAccess 8.0 releases a new generation of WebAccess HMI. Business Intelligence Dashboard, provides users with cross-platform, cross-browser data analysis and user interface based on HTML5 technology. WebAccess 8.0 can also act as an IoT Platform by providing open interfaces for partners to develop IoT applications for different vertical markets.

Product Specifications Download Spec

  • Part Number
  • Details
Graphics
  • Number of Graphic Pages
  • Variables per Graphic Pages
  • Tag Source
  • Multi-touch Gesture
Others
  • Centralized logs on project node via ODBC
  • SCADA Redundancy
  • Script language
  • Data Transfer
  • Reporting / Excel Reporting
  • Device Redundancy
  • Support IPv6
  • WebAccess Express
  • ODBC and SQL Query
Advantech WebAccess Professional
  • I/O Tag Number
  • Internal Tag Number
  • Web Client
  • Alarm Logs
  • Action Logs
Receipt
  • Recipes per Project
  • Unit per Recipe
  • Item per Unit
Web-enabled Integration
  • Video
  • Google Maps and GPS Location Tracking
Group Trend Log
  • Number of data logging
  • Alarm Groups per SCADA
Scheduler
  • Holiday Configuration Group
  • Time Zone Group
  • Device Loop Group
  • Equipment Group
  • Scheduler Reservation Group
Open Connectivity
  • Modbus Server
  • BACnet Server
  • ODBC and SQL Query
  • OPC DA/UA Server
  • DDE Server
Dashboard
  • Cross Browser and Platform
  • Number of Built-in Widget
  • Open Widget Interface
  • Widget Builder

Graphics

  • Number of Graphic Pages

    WA-P80-U600E Unlimited
    WA-X80-U000E -
    WA-X80-U075E Unlimited
    WA-X80-U15HE Unlimited
    WA-X80-U300E Unlimited
    WA-X80-U50HE Unlimited
    WA-X80-U600E Unlimited
  • Variables per Graphic Pages

    WA-P80-U600E 4000
    WA-X80-U000E -
    WA-X80-U075E 4000
    WA-X80-U15HE 4000
    WA-X80-U300E 4000
    WA-X80-U50HE 4000
    WA-X80-U600E 4000
  • Tag Source

    WA-P80-U600E Global
    WA-X80-U000E -
    WA-X80-U075E Global
    WA-X80-U15HE Global
    WA-X80-U300E Global
    WA-X80-U50HE Global
    WA-X80-U600E Global
  • Multi-touch Gesture

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes

Others

  • Centralized logs on project node via ODBC

    WA-P80-U600E Yes node via ODBC
    WA-X80-U000E -
    WA-X80-U075E Yes node via ODBC
    WA-X80-U15HE Yes node via ODBC
    WA-X80-U300E Yes node via ODBC
    WA-X80-U50HE Yes node via ODBC
    WA-X80-U600E Yes node via ODBC
  • SCADA Redundancy

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Script language

    WA-P80-U600E TclScript/VBScript/JScript
    WA-X80-U000E -
    WA-X80-U075E TclScript/VBScript/JScript
    WA-X80-U15HE TclScript/VBScript/JScript
    WA-X80-U300E TclScript/VBScript/JScript
    WA-X80-U50HE TclScript/VBScript/JScript
    WA-X80-U600E TclScript/VBScript/JScript
  • Data Transfer

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Reporting / Excel Reporting

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Device Redundancy

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Support IPv6

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • WebAccess Express

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • ODBC and SQL Query

    WA-P80-U600E -
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes

Advantech WebAccess Professional

  • I/O Tag Number

    WA-P80-U600E 600
    WA-X80-U000E -
    WA-X80-U075E 75
    WA-X80-U15HE 1500
    WA-X80-U300E 300
    WA-X80-U50HE 5000
    WA-X80-U600E 600
  • Internal Tag Number

    WA-P80-U600E 600
    WA-X80-U000E -
    WA-X80-U075E 75
    WA-X80-U15HE 1500
    WA-X80-U300E 300
    WA-X80-U50HE 5000
    WA-X80-U600E 600
  • Web Client

    WA-P80-U600E 1024
    WA-X80-U000E -
    WA-X80-U075E 1024
    WA-X80-U15HE 1024
    WA-X80-U300E 1024
    WA-X80-U50HE 1024
    WA-X80-U600E 1024
  • Alarm Logs

    WA-P80-U600E 5000
    WA-X80-U000E -
    WA-X80-U075E 5000
    WA-X80-U15HE 5000
    WA-X80-U300E 5000
    WA-X80-U50HE 5000
    WA-X80-U600E 5000
  • Action Logs

    WA-P80-U600E 5000
    WA-X80-U000E -
    WA-X80-U075E -
    WA-X80-U15HE -
    WA-X80-U300E -
    WA-X80-U50HE -
    WA-X80-U600E -

Receipt

  • Recipes per Project

    WA-P80-U600E Unlimited
    WA-X80-U000E -
    WA-X80-U075E Unlimited
    WA-X80-U15HE Unlimited
    WA-X80-U300E Unlimited
    WA-X80-U50HE Unlimited
    WA-X80-U600E Unlimited
  • Unit per Recipe

    WA-P80-U600E 999
    WA-X80-U000E -
    WA-X80-U075E 999
    WA-X80-U15HE 999
    WA-X80-U300E 999
    WA-X80-U50HE 999
    WA-X80-U600E 999
  • Item per Unit

    WA-P80-U600E 999
    WA-X80-U000E -
    WA-X80-U075E 999
    WA-X80-U15HE 999
    WA-X80-U300E 999
    WA-X80-U50HE 999
    WA-X80-U600E 999

Web-enabled Integration

  • Video

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Google Maps and GPS Location Tracking

    WA-P80-U600E Yes
    WA-X80-U000E Yes
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes

Group Trend Log

  • Number of data logging

    WA-P80-U600E Number of IO tags license x 2
    WA-X80-U000E -
    WA-X80-U075E Number of IO tags license x 2
    WA-X80-U15HE Number of IO tags license x 2
    WA-X80-U300E Number of IO tags license x 2
    WA-X80-U50HE Number of IO tags license x 2
    WA-X80-U600E Number of IO tags license x 2
  • Alarm Groups per SCADA

    WA-P80-U600E 9999
    WA-X80-U000E -
    WA-X80-U075E 9999
    WA-X80-U15HE 9999
    WA-X80-U300E 9999
    WA-X80-U50HE 9999
    WA-X80-U600E 9999

Scheduler

  • Holiday Configuration Group

    WA-P80-U600E 9999
    WA-X80-U000E -
    WA-X80-U075E 9999
    WA-X80-U15HE 9999
    WA-X80-U300E 9999
    WA-X80-U50HE 9999
    WA-X80-U600E 9999
  • Time Zone Group

    WA-P80-U600E 9999
    WA-X80-U000E -
    WA-X80-U075E 9999
    WA-X80-U15HE 9999
    WA-X80-U300E 9999
    WA-X80-U50HE 9999
    WA-X80-U600E 9999
  • Device Loop Group

    WA-P80-U600E 9999
    WA-X80-U000E -
    WA-X80-U075E 9999
    WA-X80-U15HE 9999
    WA-X80-U300E 9999
    WA-X80-U50HE 9999
    WA-X80-U600E 9999
  • Equipment Group

    WA-P80-U600E 9999
    WA-X80-U000E -
    WA-X80-U075E 9999
    WA-X80-U15HE 9999
    WA-X80-U300E 9999
    WA-X80-U50HE 9999
    WA-X80-U600E 9999
  • Scheduler Reservation Group

    WA-P80-U600E 9999
    WA-X80-U000E -
    WA-X80-U075E 9999
    WA-X80-U15HE 9999
    WA-X80-U300E 9999
    WA-X80-U50HE 9999
    WA-X80-U600E 9999

Open Connectivity

  • Modbus Server

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • BACnet Server

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • ODBC and SQL Query

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • OPC DA/UA Server

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • DDE Server

    WA-P80-U600E Yes
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes

Dashboard

  • Cross Browser and Platform

    WA-P80-U600E Yes
    WA-X80-U000E No
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Number of Built-in Widget

    WA-P80-U600E 37
    WA-X80-U000E No
    WA-X80-U075E 42
    WA-X80-U15HE 42
    WA-X80-U300E 42
    WA-X80-U50HE 42
    WA-X80-U600E 42
  • Open Widget Interface

    WA-P80-U600E Yes
    WA-X80-U000E No
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes
  • Widget Builder

    WA-P80-U600E -
    WA-X80-U000E -
    WA-X80-U075E Yes
    WA-X80-U15HE Yes
    WA-X80-U300E Yes
    WA-X80-U50HE Yes
    WA-X80-U600E Yes

Related Materials

Featured Highlights

  • Advantech WebAccess

    Advantech WebAccess

    Advantech WebAccess, as the core of Advantech’s IoT solution, provides users with a cross-platform, cross-browser data access experience and a user interface based on HTML5 technology. With WebAccess, users can build an information management platform and improve the effectiveness of vertical markets’ development and management.