EKI-1321

1-port RS-232/422/485 to GPRS IP Gateway
  • Universal quad-band GSM/GPRS 850/900/1800/1900 MHz
  • Dual SIM for telecom redundancy
  • Support SDHC SD Card for Data Buffering
  • Connect Ethernet and Serial Devices over VPN
  • Various operation modes: COM port redirector, RVCOM, TCP, UDP, SMS tunnel, and pair connection
  • Any baud rate setting for easy configuration
  • Supports Universal quad-band GSM/GPRS 850/900/1800/1900 MHz
  • Built-in 15 KV ESD protection for all serial signals
  • 1.5 KV isolation protection
  • 2 digital inputs
  • Multiple configuration methods: Windows utility, Telnet, and Web console
  • Supports 32-bit/64-bit Windows 2000/XP/Vista/7, Windows Server 2003/2008, Windows CE 5.0, and Linux
EKI-1321 and EKI-1322 cellular gateways can transparently bring RS-232/422/485 or Ethernet devices to a cellular network. They allow nearly any device with serial or Ethernet ports to connect and share a cellular network with easy and simple configuration. EKI-1321 and EKI-1322 GPRS IP Gateway's are compact, and can be DIN-rail or wall mounted and with both front panel and side panel LED displays for easy identification. They come with dual DC power input from 12 to 48 VDC and have 2 KV EFT/Surge protection to prevent damage from various type of power resources. The serial ports are also protected by 15 KV ESD line protection to keep your system safe from unexpected electrical discharges. Both models support dual SIM slots to support GPRS signal redundancy to switch to an available channel automatically while the existing one is disconnected, and SD card slot for data buffering to prevent loss of serial data while the communication is interrupted.

Product Specifications Download Spec

  • Part Number
  • Details
Cellular Interface
  • Band Option
  • GPRS Coding Schemes
  • GPRS Multi-Slot
  • GPRS Terminal Device
  • No. of SIM
  • SIM Control
  • Standards
  • Tx Power
Digital Input
  • Channels
  • Input Level
Environment
  • Operating Humidity
  • Operating Temperature
  • Storage Temperature
General
  • LED Indicators
  • Reboot Trigger
LAN Interface
  • Connector
  • Ethernet
  • Protection
Mechanics
  • Dimensions (W x H x D)
  • Enclosure
  • Mounting
  • Weight
Power Requirements
  • Power Connector
  • Power Consumption
  • Power EFT/Surge Prot.
  • Power Input
Relay Output
  • Channels
  • Contact Rating
  • Relay off Time(Typ.)
  • Relay on Time(Typ.)
Serial Communication
  • Baud Rate
  • Data Bits
  • No. of Ports
  • Parity
  • Port Connector
  • Port Type
  • Protection
  • Serial Signals
  • Stop Bits
Software
  • Configuration
  • Driver Support
  • Operation Modes
  • Protocols
  • Router/Firewall
  • Utility Software

Cellular Interface

  • Band Option

    EKI-1321-AE Quad-band 850/900 and 1800/1900 MHz
  • GPRS Coding Schemes

    EKI-1321-AE CS1 ~ CS4
  • GPRS Multi-Slot

    EKI-1321-AE Class 10
  • GPRS Terminal Device

    EKI-1321-AE Class B
  • No. of SIM

    EKI-1321-AE 2
  • SIM Control

    EKI-1321-AE 3 V
  • Standards

    EKI-1321-AE GSM/GPRS
  • Tx Power

    EKI-1321-AE 1 W for GSM 1800/1900, 2 W for EGSM 850/900

Digital Input

  • Channels

    EKI-1321-AE 2
  • Input Level

    EKI-1321-AE Logic level 0: 1 V Maximum, Logic level 1: 3 ~ 30 V

Environment

  • Operating Humidity

    EKI-1321-AE 5 ~ 95% RH
  • Operating Temperature

    EKI-1321-AE -30 ~ 65°C (-22 ~ 149°F)
  • Storage Temperature

    EKI-1321-AE -40 ~ 75°C (-40 ~ 167°F)

General

  • LED Indicators

    EKI-1321-AE System: Power, System Status, GPRS: Quality, GPRS ready; Serial: Tx, Rx
  • Reboot Trigger

    EKI-1321-AE Built-in WDT (watchdog timer)

LAN Interface

  • Connector

    EKI-1321-AE RJ45
  • Ethernet

    EKI-1321-AE 10/100 Mbps, auto MDI/MDIX
  • Protection

    EKI-1321-AE 1.5 KV built-in magnetic isolation protection

Mechanics

  • Dimensions (W x H x D)

    EKI-1321-AE 27 x 120 x 85 mm (1.06" x 4.72" x 3.35")
  • Enclosure

    EKI-1321-AE Metal with solid mounting hardware
  • Mounting

    EKI-1321-AE DIN-rail, Wall
  • Weight

    EKI-1321-AE 0.49 Kg

Power Requirements

  • Power Connector

    EKI-1321-AE Terminal block
  • Power Consumption

    EKI-1321-AE 8W
  • Power EFT/Surge Prot.

    EKI-1321-AE 2 KV
  • Power Input

    EKI-1321-AE 12 ~ 48 VDC, redundant dual inputs

Relay Output

  • Channels

    EKI-1321-AE 1
  • Contact Rating

    EKI-1321-AE 0.5 A @ 120 VAC
  • Relay off Time(Typ.)

    EKI-1321-AE 4 ms
  • Relay on Time(Typ.)

    EKI-1321-AE 3 ms

Serial Communication

  • Baud Rate

    EKI-1321-AE 75 bps to 921.6 kbps, any baud rate setting
  • Data Bits

    EKI-1321-AE 5, 6, 7, 8
  • No. of Ports

    EKI-1321-AE 1, 2 KV isolation protection
  • Parity

    EKI-1321-AE None, Odd, Even, Space, Mark
  • Port Connector

    EKI-1321-AE DB9 male
  • Port Type

    EKI-1321-AE RS-232/422/485, software selectable
  • Protection

    EKI-1321-AE 15 KV ESD for all signals
  • Serial Signals

    EKI-1321-AE RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND, RS-422: TxD+, TxD-, RxD+, RxD-, GND, RS-485: Data+, Data-, GND
  • Stop Bits

    EKI-1321-AE 1, 1.5, 2

Software

  • Configuration

    EKI-1321-AE Windows utility, Telnet console, Web Browser
  • Driver Support

    EKI-1321-AE 32-bit/64-bit Windows 2000/XP/Vista/7, Windows Server 2003/2008, Windows CE 5.0, and Linux
  • Operation Modes

    EKI-1321-AE Virtual COM, Reverse Virtual COM, TCP/UDP server mode, TCP/UDP client mode, Pair connection mode (Serial Tunnel), RFC2217, SMS Tunnel, IP Gateway w/ VPN
  • Protocols

    EKI-1321-AE ICMP, TCP/IP, UDP, DHCP Client, Telnet, DNS, SNMP, HTTP, HTTPS, SMTP, SNTP, ARP, SSL
  • Router/Firewall

    EKI-1321-AE NAT, port forwarding
  • Utility Software

    EKI-1321-AE Advantech Serial Device Server Configuration Utility

Need more info? Talk to our Online Rep!

Related Materials

Contact Advantech

1-888-576-9668
(800) 866-6008
800-346-3119

Contact Advantech