MyAdvantech Registration

MyAdvantech is a personalized portal for Advantech customers. By becoming an Advantech member, you can receive latest product news, webinar invitations and special eStore offers.

Sign up today to get 24/7 quick access to your account information.

RS-485 I/O Modules: ADAM-4000

Advantech’s RS-485 I/O Modules, ADAM-4000 series, are the perfect choice for establishing a cost-effective remote I/O system. Customers can benefit from ADAM-4000 modules through its simple wiring using only two wires to communicate with their controller or other RS-485 devices. ADAM-4000 modules use the EIA RS-485 communication protocol; the industry's most widely used bi-directional, balanced transmission line suitable for industrial environments.

Product Categories

  • Robust Remote I/O Modules

    ADAM-4100 series I/O modules are compact and versatile sensor-to-computer interface units. They are designed for reliable operation in harsh environments, and can operate normally in wide temperatures from -40 to 85°C, with wide power input and resistance against noise-interference.

  • Analog I/O Modules

    Analog input modules provide various sources of input, such as thermocouple, RTD, thermistor or general analog signals. These modules use EIA RS-485 communication protocol – the widely used bi-directional, balanced transmission line standard in the industry. ADAM-4000 supports Modbus / RTU protocol as a remote data transmission mechanism as well.

    • ADAM-4011

      Analog input modules use a microprocessor-controlled integrating A/D converter to convert sensor voltage, current, thermocouple, or RTD signals into digital data. The digital data is then translated into either engineering units, twos complement hexadecimal format or percentage of full-scale range (FSR)according to the module ’s configuration. When prompted by the host computer, the data is sent through a standard RS-485 interface. The Analog Input Modules offer signal conditioning, A/D conversion, ranging, and RS-485 digital communication functions. They protect your equipment from ground loops and power surges by providing opto-isolation of the A/D input and transformer based isolation up to 3000 V DC . (ADAM-4011 has transformer-based isolation up to 500 V DC )
    • ADAM-4012

      Analog input modules use a microprocessor-controlled integrating A/D converter to convert sensor voltage, or current signals into digital data. The digital data is then translated into either engineering units, twos complement hexadecimal format or percentage of full-scale range (FSR)according to the module ’s configuration. When prompted by the host computer, the data is sent through a standard RS-485 interface. The Analog Input Modules offer signal conditioning, A/D conversion, ranging, and RS-485 digital communication functions. They protect your equipment from ground loops and power surges by providing opto-isolation of the A/D input and transformer based isolation up to 3000 V DC .
    • ADAM-4013

      Analog input modules use a microprocessor-controlled integrating A/D converter to convert sensor voltage, current, or RTD signals into digital data. The digital data is then translated into either engineering units, twos complement hexadecimal format or percentage of full-scale range (FSR)according to the module ’s configuration. When prompted by the host computer, the data is sent through a standard RS-485 interface. The Analog Input Modules offer signal conditioning, A/D conversion, ranging, and RS-485 digital communication functions. They protect your equipment from ground loops and power surges by providing opto-isolation of the A/D input and transformer based isolation up to 3000 V DC .
    • ADAM-4015

      A RTD module is popular for temperature measurement. Unlike tranditional designs, the ADAM-4015 provides six RTD input channels for different types of RTD signal as an cost-effective solution in industrial & building automation. Occasionally, broken external wiring will lead to inaccurate current value. The ADAM-4015 provides a broken wiring detection function so users can easily troubleshoot broken wiring problems.
    • ADAM-4015T

      6-channel Thermistor Module with Modbus
    • ADAM-4016

      A strain gauge input module uses a microprocessor-controlled integrating A/D converter to convert sensor voltage or current signals into digital data for load cell and stress measurement. The digital data is then translated into either engineering units, twos complement hexadecimal format or percent-age of full-scale range (FSR)according to the module ’s configuration. When prompted by the host computer, the data is sent through a standard RS-485 interface. The strain gauge input module offers signal conditioning, A/D conversion, ranging, and RS-485 digital communication functions. They protect your equipment from ground loops and power surges by providing opto-isolation of the A/D input and transformer based isolation up to 3000 VDC .
    • ADAM-4017

      The ADAM-4017 is a 16-bit, 8-channel analog input module that provides programmable input ranges on all channels. This module is an extremely cost-effective solution for industrial measurement and monitoring applications. Its opto-isolated inputs provide 3000 VDC of isolation between the analog input and the module, protecting the module and peripherals from damage due to high input-line voltages. ADAM-4017 offers signal conditioning, A/D conversion, ranging and RS-485 digital communication functions. The module protects your equipment from ground loops and power surges by providing optoisolation of A/D input and transformer based isolation up to 3000 VDC. The ADAM-4017 uses a 16-bit microprocessor-controlled sigma-delta A/D converter to convert sensor voltage or current into digital data. The digital data is then translated into engineering units. When prompted by the host computer, the module sends the data to the host through a standard RS-485 interface.
    • ADAM-4017+

      The ADAM-4017+ is a 16-bit, 8-channel analog input module that provides programmable input ranges on all channels. These modules are an extremely cost-effective solution for industrial measurement and monitoring applications. 3000 VDC optical isolation between the analog input and the modules protects the modules and peripherals from damages caused by high input voltages.
    • ADAM-4018

      The ADAM-4017/4018 is a 16-bit,8-channel analog input module that provides programmable input ranges on all channels. This module is an extremely cost-effective solution for industrial measurement and monitoring applications. Its opto-isolated inputs provide 3000 V DC of isolation between the analog input and the module, protecting the module and peripherals from damage due to high input voltages. ADAM-4017/4018 offers signal conditioning, A/D conversion, ranging and RS-485 digital communication functions. The module protects your equipment from ground loops and power surges by providing opto-isolation of A/D input and transformer based isolation up to 3000 V DC . The ADAM-4017/4018 uses a 16-bit microprocessor-controlled sigma-delta A/D converter to convert sensor voltage or current into digital data. The digital data is then translated into engineering units. When prompted by the host computer, the module sends the data to the host through a standard RS-485 interface.
    • ADAM-4018+

      The ADAM-4018+ is a 16-bit, 8-channel analog input module that provides programmable input ranges on all channels. These modules are an extremely cost-effective solution for industrial measurement and monitoring applications. 3000 VDC optical isolation between the analog input and the modules protects the modules and peripherals from damages caused by high input voltages.
    • ADAM-4019+

      ADAM-4019+ is an 8-channel Universal Analog Input Module. The new module improves over its predecessor ADAM-4019 with a 4~20 mA input range, and a burnout detection function. Its mixed input range design supports individual configuration for each channel to save costs and space in applications. The other frequently used input ranges include +/-10V, mV, and thermocouple, which are all well-integrated in this model. It also supports burnout detection so that any sensor failures can be detected in advance. For easier control, ADAM-4019+ provides not only ADAM ASCII commands, but also the Modbus/RTU protocol for satisfying different application demands.
    • ADAM-4021

      Analog output module receives its digital input through an RS-485 interface from the host computer. The format of the data is either engineering units, twos complement hexadecimal format or percentage of full-scale range (FSR),depending on the module ’s configuration. It then uses its microprocessor-controlled D/A converter to convert the digital data into output signals. You get a true readback of the analog output signal from the unit ’s ADC, which independently monitors the output. You can specify slew rates and start up currents through the configuration software. The Analog Output Module can supply single-channel analog output in a range of voltages or currents. They protect your equipment from ground loops and power surges by providing opto-isolation of the D/A output. The transformer based isolation is up to 3000 VDC.
    • ADAM-4022T

      The ADAM-4022T dual loop PID controller is a Serial-based controller. It was designed as the product of Advantech’s ADAM-4000 series with Serial based PID controller. With an excellent accuracy ±0.15%, the ADAM-4022T is an ideal controller for temperature and other processing variable in heating and cooling applications and environmental tests. ADAM-4022T utility software can help you select input and range configurations, set the operating parameter (SP, Sv, Pv ….. etc) for your process control needed. ADAM-4022T utility software also integrates the trend chart to help you monitor and debug your control setting. ADAM-4022T was designed to use in industrial environment. It can be installed on the standard DIN rail inside the cabinet. And it can be powered by unregulated 10~30Vdc to meet the various power supplied source in field. It also withstands ambient temperature up to 60 o C and resists the effects of vibration and mechanical shock.
    • ADAM-4024

      ADAM-4024 provides 4 universal type output channels. Moreover, it is designed with 4 Digital inputs for integrating applications, such as emergency latch outputs or users default triggers. It uses optical isolators to prevent ground loop effects and limits damages from power surges. You can specify slew rates and startup currents.
  • Digital I/O Modules

    The Advantech ADAM-4000 digital input/output modules provide isolation and fault protection, which secure a stable operation.

    • ADAM-4050

      The ADAM-4050 features seven digital input channels and eight digital output channels. The outputs are open-collector transistor switches that you can control from the host computer. You can also use the switches to control solid-state relays, which in turn can control heaters, pumps and power equipment. The host computer can use the module's digital inputs to determine the state of limit or safety switches or remote digital signals.
    • ADAM-4051

      The ADAM-4051 is a 16-ch. Digital Input Module, built with 2500 VDC optical isolation, suitable for critical applications. Different from other modules, the ADAM-4051 accepts 10~50V input voltage to fit various digital signals, such as 12 VDC, 24 VDC, 48 VDC. Moreover, users can read the current status from the LED indications on the front panel.
    • ADAM-4052

      The ADAM-4052 provides eight digital input channels: six fully independent isolated channels and two isolated channels with a common ground. All have 5000 V RMS isolation to prevent ground loop effects and prevent damage from power surges on the input lines.
    • ADAM-4053

      The ADAM-4053 provides 16 digital input channels for dry contact or wet contact signals. For dry contact, effective distance from DI to contact point is up to 500 m.
    • ADAM-4055

      The ADAM-4055 offers 8-ch. isolated digital inputs and 8-ch. isolated digital outputs for critical applications. The inputs accept 10~50 V voltage, and the outputs supply 5~40 VDC open collector. Considered to be user-friendly. The ADAM-4055 is also built with LED indicator for easy status reading.
    • ADAM-4056S

      12-ch Sink Type Isolated Digital Output Module with Modbus
    • ADAM-4056SO

      12-channel Source Type Isolated Digital Output Module
    • ADAM-4060

      The ADAM Relay Output Module is a low-cost alternative to SSR modules. The ADAM Relay Output Module provides four relay channels, two of Form A and two of Form C. This module is excellent for ON/OFF control or low-power switching applications.
    • ADAM-4068

      The ADAM-4068 relay module is controlled remotely and store configuration data in EEPROM. The ADAM-4068 provides 4/8 channels, half being Form A and the rest being Form C. These modules are excellent for on/off control or low-power switching applications.
    • ADAM-4069

      ADAM-4069 is designed for on/off control in high-voltage applications. The major feature of ADAM-4069 is its power relay rating at 240 V AC and 5 A. This range can satisfy most requirements for driving externally controlled devices such as lights, fans, alarm systems, and various electronic devices in industrial automation, security, building and home automation applications. ADAM-4069 also supports the Modbus/RTU protocol and ADAM ASCII commands. Besides, it provides four form A channels and four form C channels.
    • ADAM-4080

      ADAM-4080/4080D Counter/frequency input module has two 32-bit counter input channels (counter 0 and counter 1)with built-in programmable timer for frequency measurement. These cost-effective modules let you monitor counter/frequency data as measurements are taken.

Related Materials