EKI-1242IEIMS
Modbus RTU/TCP to EtherNet/IP Protocol Gateway - Wide Temperature

  • Seamless integrate Modbus RTU/TCP and EtherNet/IP communication
  • Built-in real time diagnostic to increase high efficiency of device management
  • Designed for protocol extensibility and adaption
  • Modbus TCP scanner mode supports 64 connections
  • Supports dual power input for power redundancy
  • Mounts on DIN-rail and Wall mount
The EKI-1242EIMS Industrial Protocol gateway not only provides seamless communication between Fieldbus and Industrial Ethernet but also supports different protocol devices. Therefore, the Fieldbus gateway can integrate new and existing Modbus RTU/TCP devices to the EtherNet/IP network. Being able to collect data and exchange data between Modbus RTU/TCP to EtherNet/IP, EKI-1242EIMS is a simple and resource saving way to bring the advantages of fast data transmissions between different devices.

製品詳細 詳細ダウンロード

  • パーツナンバー
  • 詳細
Certification
  • EMC
  • EMI
  • EMS
  • Freefall
  • Shock
  • Vibration
Environment
  • Humidity (Operating Range)
  • Temperature (Max. Operating)
  • Temperature (Min. Operating)
  • Temperature (Operating Range)
  • Temperature (Storage Range)
Ethernet Communication
  • Ethernet Standard
  • RJ-45 Port Connector Type
  • RJ-45 Port Number
  • RJ-45 Transmission Speed
Protection
  • Port to Port Isolation
  • Reverse Polarity
Mechanism
  • Dimensions (W x H x D)
  • Enclosure (Metal)
  • Mounting (DIN-rail)
  • Mounting (Wall)
  • IP Rating
  • Weight
Modbus Communication
  • Modbus RTU/TCP Functions Support
  • Modbus RTU/TCP Mode
Power
  • Power Consumption
  • Power Operating Current
  • Power Input (DC)
Serial Communication
  • Data Bits
  • Flow Control
  • Parity
  • Serial Port Connector Type
  • Serial Port Number
  • RS-232
  • RS-422
  • RS-485
  • Serial Signals
  • Stop Bits
  • Serial Transmission Speed
Software
  • EtherNet/IP Class
  • EtherNet/IP Max. No. of Connection
  • EtherNet/IP Max. Total I/O Data Size
  • Modbus RTU/TCP Functions Support
  • Modbus RTU/TCP Max. No. of Connections
  • Modbus RTU/TCP Mode
Warranty
  • Warranty Period
Protocol Support
  • Modbus TCP
  • Modbus RTU
  • EtherNet/IP
  • Ethernet
  • Modbus ASCII

Certification

  • EMC

    EKI-1242IEIMS-A CE, FCC Class A
  • EMI

    EKI-1242IEIMS-A EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A
  • EMS

    EKI-1242IEIMS-A EN 61000-4-2 (Level 4), EN 61000-4-3 (Level 3), EN 61000-4-4 (Level 4), EN 61000-4-5 (Level 4), EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 4)
  • Freefall

    EKI-1242IEIMS-A IEC 60068-2-32
  • Shock

    EKI-1242IEIMS-A IEC 60068-2-27
  • Vibration

    EKI-1242IEIMS-A IEC 60068-2-6

Environment

  • Humidity (Operating Range)

    EKI-1242IEIMS-A 10~90% RH non-condensing (refer to IEC 60068-2-3)
  • Temperature (Max. Operating)

    EKI-1242IEIMS-A 75°C (167°F)
  • Temperature (Min. Operating)

    EKI-1242IEIMS-A -40°C (-40°F)
  • Temperature (Operating Range)

    EKI-1242IEIMS-A -40 ~ 75°C (-40 ~ 167°F)
  • Temperature (Storage Range)

    EKI-1242IEIMS-A -40 ~ 85°C (-40 ~ 185°F)

Ethernet Communication

  • Ethernet Standard

    EKI-1242IEIMS-A IEEE 802.3 , 802.3ab , 802.3u
  • RJ-45 Port Connector Type

    EKI-1242IEIMS-A RJ-45
  • RJ-45 Port Number

    EKI-1242IEIMS-A 4
  • RJ-45 Transmission Speed

    EKI-1242IEIMS-A 10/100 Mbps

Protection

  • Port to Port Isolation

    EKI-1242IEIMS-A Built-in 1.5 KV magnetic isolation
  • Reverse Polarity

    EKI-1242IEIMS-A Present

Mechanism

  • Dimensions (W x H x D)

    EKI-1242IEIMS-A 42 x 140 x 95 mm (1.65 x 5.51 x 3.74 in.)
  • Enclosure (Metal)

    EKI-1242IEIMS-A Metal with solid mounting hardware
  • Mounting (DIN-rail)

    EKI-1242IEIMS-A Yes
  • Mounting (Wall)

    EKI-1242IEIMS-A Yes
  • IP Rating

    EKI-1242IEIMS-A IP30
  • Weight

    EKI-1242IEIMS-A 0.497 kg

Modbus Communication

  • Modbus RTU/TCP Functions Support

    EKI-1242IEIMS-A 1,2,3,4,5,6,15,16,23
  • Modbus RTU/TCP Mode

    EKI-1242IEIMS-A Client

Power

  • Power Consumption

    EKI-1242IEIMS-A 5.2W (system)
  • Power Operating Current

    EKI-1242IEIMS-A 0.22 @ 24V ;  0.11 @ 48V
  • Power Input (DC)

    EKI-1242IEIMS-A 12 ~ 48 VDC

Serial Communication

  • Data Bits

    EKI-1242IEIMS-A 7, 8
  • Flow Control

    EKI-1242IEIMS-A XON/XOFF, RTS/CTS, DTR/DSR
  • Parity

    EKI-1242IEIMS-A None, Odd, Even, Space, Mark
  • Serial Port Connector Type

    EKI-1242IEIMS-A DB9 male
  • Serial Port Number

    EKI-1242IEIMS-A 2
  • RS-232

    EKI-1242IEIMS-A Yes
  • RS-422

    EKI-1242IEIMS-A Yes
  • RS-485

    EKI-1242IEIMS-A Yes
  • Serial Signals

    EKI-1242IEIMS-A RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
  • Stop Bits

    EKI-1242IEIMS-A 1, 2
  • Serial Transmission Speed

    EKI-1242IEIMS-A 50 ~ 921.6 kbps, any baud rate setting

Software

  • EtherNet/IP Class

    EKI-1242IEIMS-A Adaper
  • EtherNet/IP Max. No. of Connection

    EKI-1242IEIMS-A 32 explicit messaging, 5 implicit messaging
  • EtherNet/IP Max. Total I/O Data Size

    EKI-1242IEIMS-A Input: 496 bytes
  • Modbus RTU/TCP Functions Support

    EKI-1242IEIMS-A 1, 2, 3, 4, 5, 6, 15, 16, 23
  • Modbus RTU/TCP Max. No. of Connections

    EKI-1242IEIMS-A 64 connections
  • Modbus RTU/TCP Mode

    EKI-1242IEIMS-A Client

Warranty

  • Warranty Period

    EKI-1242IEIMS-A 5 years

Protocol Support

  • Modbus TCP

    EKI-1242IEIMS-A Yes
  • Modbus RTU

    EKI-1242IEIMS-A Yes
  • EtherNet/IP

    EKI-1242IEIMS-A Yes
  • Ethernet

    EKI-1242IEIMS-A Yes
  • Modbus ASCII

    EKI-1242IEIMS-A Yes