When link two machines or communicate with server in heavy loading,
PCA-6154 Rev.A3 sometimes has communication error problem.
The network firmware configuration causes the problem on
RTL8139A of PCA-6154 Rev. A3.
Please follow the following process:
#### Modification process #############
Update the new firmware of the network can make system link
more stable. Please do the following steps
Upgraded EE PROM configuration (RTL8139A) :
1. Copy all the attached files into your disk ( please use the new attached
files, not the ones
in my previous email ).
2. Run " NewID 8139A.cfg " to reassign the ID Code (Please type the number
as same as printed in the lable on the RTL 8139A chip ).
3. Run " PG8139.exe " to reconfigure the EEPROM
4. Please make sure that your "L2 cache memory" is set to be "7 bit" in
CMOS setting.
Thank you for your feedback
We will look over your massage and get back to you soon if you need further assistance!